Skip to Content

P117 · Portable

Economical portable flow measurement.

An economical portable ultrasonic flow meter with clamp-on transducers and sensor magnet rails, offering cost-effective accuracy.

P117 ultrasonic measurement instrument

At a glance

What P117 does, in plain words.

What it measures
Liquid flow
How much liquid moves through the pipe.
How it installs
Clamp-on
Sensors fit on the outside of the pipe, so the pipe stays closed.
How it connects
On-device storage
Readings are shown on screen and stored on the device.
Pipe sizes
DN25–DN1200
DN is the nominal pipe size, roughly the inside diameter in millimetres.

Why P117

P117 in short.

An economical portable ultrasonic flow meter with clamp-on transducers and sensor magnet rails, offering cost-effective accuracy. Designed for ease of use and reliability, it installs and operates simply across diverse industrial applications.

Where it is used
  • Water, sewage (low particle content) and seawater
  • Water plants
  • Sewage treatment plants
  • Plant irrigation
  • Cooling water
  • Energy-saving monitoring
  • Water-saving management

How it works

Sound with the flow arrives sooner.

Two sensors on the same side of the pipe take turns sending sound through the water. Sound travelling with the flow arrives slightly sooner than sound travelling against it; the meter turns that time difference into flow, which is why it needs to know your pipe.

Pipe & installation

What the meter needs to know about your pipe.

These are set up on the meter after installation. Pipe size and transducer type are decided when ordering.

Pipe & installation guide pipe materials, sizes, setup checklist

Stainless steel · 2″ example

A smooth metal surface. Clean the spot, add coupling gel, then clamp the sensor on.

60.3mmacross the outside
2.8mmwall thickness
54.8mmacross the inside

Pipe sizes are names, not measurements: a 2″ pipe is 2.375″ across.

The meter needs Pipe size Wall thickness Material: Stainless steel
Technical details standards, OD / ID, both units
Standard
ASME B36.19 · 2″ Sch 10S
Outside diameter (OD)
2.375″ (60.33 mm)
Wall
0.109″ (2.77 mm)
Inside diameter (ID)
2.157″ (54.79 mm)
Meter parameters
OD · wall · material

This guide shows what a clamp-on meter needs to know about a pipe. It does not mean every model fits every pipe: check the specifications below or ask an engineer.

Specifications

Check the fit before you specify.

The short version is above. These are the specifications published for P117; values that are still being checked are left out.

Performance

Flow velocity
0.01–6 m/s (0.03–20 ft/s)
Pipe size
25–1200 mm (1″–48″)
Accuracy
±1% of reading (0.5–5 m/s)
Repeatability
0.2%
Pipe material
Carbon steel, stainless steel, cast iron, ductile iron, copper, PVC, aluminium, asbestos, fibreglass-epoxy

Function

Communication
RS485 with Modbus protocol
Analogue output
4–20 mA, max. load 500 Ω
Data storage
TF card, more than 1000 days
Power supply
10.8 V rechargeable lithium battery

Physical

Ambient temperature
−10 °C to 50 °C (14 °F to 122 °F)
Transducer temperature
0 °C to 80 °C (32 °F to 176 °F), standard
Ingress protection
Transmitter IP54, transducer IP68
Transducer cable
5 m (16.4 ft) standard

Need a value that is not listed, or the datasheet for your configuration? Ask an engineer.

What these terms mean
DN
Nominal pipe size, roughly the inside diameter in millimetres (DN50 ≈ 50 mm).
Clamp-on
Sensors strap to the outside of the pipe. No cutting, no shutdown for installation.
PoE
Power over Ethernet: one network cable carries power and data.
LoRaWAN
Long-range, low-power wireless. Readings travel through a gateway to a network server.
Modbus RS485
A wired connection widely used by building and industrial control systems.
4–20 mA
An analogue signal where the current represents the reading.

Documents

Datasheets and manuals.

No reviewed documents are published for P117 yet.

Request the current datasheet or manual →

Compare

A different job may need a different meter.

Compare P117 with others

Is this the right meter for your system?

Share your pipe, liquid temperature and connection requirements with our engineers.