Skip to Content

Compare

Compare models side by side.

Up to 3 models. Rows that differ are highlighted. Values that are not confirmed yet are marked, so nothing is guessed.

Specification
P117
P117 Portable · economical Remove P117
What it measures Liquid flow
Typical use Site surveys
Data connection On-device storage
Installation type Clamp-on
Pipe sizes DN25–DN1200
Reviewed specifications
Flow velocity 0.01–6 m/s (0.03–20 ft/s)
Pipe size 25–1200 mm (1″–48″)
Accuracy ±1% of reading (0.5–5 m/s)
Repeatability 0.2%
Pipe material Carbon steel, stainless steel, cast iron, ductile iron, copper, PVC, aluminium, asbestos, fibreglass-epoxy
Communication RS485 with Modbus protocol
Analogue output 4–20 mA, max. load 500 Ω
Data storage TF card, more than 1000 days
Power supply 10.8 V rechargeable lithium battery
Ambient temperature −10 °C to 50 °C (14 °F to 122 °F)
Transducer temperature 0 °C to 80 °C (32 °F to 176 °F), standard
Ingress protection Transmitter IP54, transducer IP68
Transducer cable 5 m (16.4 ft) standard