D348D Plus · Fixed flow

Multi-path measurement, one to six channels.

A high-accuracy multi-path ultrasonic flow meter for precise liquid measurement across industries.

D348D Plus ultrasonic measurement instrument

At a glance

What D348D Plus does, in plain words.

What it measures
Liquid flow
How much liquid moves through the pipe.
How it installs
Not confirmed yet
Ask an engineer for this model.
How it connects
RS485 / 4–20 mA
Wired into control systems over Modbus RS485, or as a 4–20 mA signal.
Pipe sizes
DN25–DN5000
DN is the nominal pipe size, roughly the inside diameter in millimetres.

Why D348D Plus

D348D Plus in short.

A high-accuracy multi-path ultrasonic flow meter for precise liquid measurement across industries. With 1 to 6 channels it uses advanced ultrasonic technology for high accuracy, and the robust design and user-friendly interface simplify installation and maintenance. Suited to water management, chemical processing and more.

Where it is used
  • Water, sewage (low particle content) and seawater
  • Water plants
  • Sewage treatment plants
  • Plant irrigation
  • Cooling water
  • Energy-saving monitoring
  • Water-saving management

Specifications

Check the fit before you specify.

The short version is above. These are the specifications published for D348D Plus; values that are still being checked are left out.

Performance

Flow velocity
±0.01 to ±7 m/s (±0.03 to ±23 ft/s)
Pipe size
25–5000 mm (1″–200″)
Accuracy
±0.5% of reading (0.5–5 m/s)
Repeatability
0.1%
Pipe material
Carbon steel, stainless steel, cast iron, ductile iron, copper, PVC, aluminium, asbestos, fibreglass-epoxy

Function

Communication
RS485 with Modbus protocol
Analogue output
4–20 mA, max. load 750 Ω
Pulse output
0–9999 Hz, OCT, adjustable frequency limits
Relay output
Max. 1 Hz, 1 A at 125 VAC or 2 A at 30 VDC
Data storage
TF card, more than 1000 days
Power supply
90–250 VAC (48–63 Hz) or 10–36 VDC

Physical

Ambient temperature
−10 °C to 50 °C (14 °F to 122 °F)
Transducer temperature
−40 °C to 80 °C (−40 °F to 176 °F), standard
Ingress protection
Transmitter IP65, transducer IP68
Transducer cable
9 m (29.5 ft) standard

Need a value that is not listed, or the datasheet for your configuration? Ask an engineer.

What these terms mean
DN
Nominal pipe size, roughly the inside diameter in millimetres (DN50 ≈ 50 mm).
Clamp-on
Sensors strap to the outside of the pipe. No cutting, no shutdown for installation.
PoE
Power over Ethernet: one network cable carries power and data.
LoRaWAN
Long-range, low-power wireless. Readings travel through a gateway to a network server.
Modbus RS485
A wired connection widely used by building and industrial control systems.
4–20 mA
An analogue signal where the current represents the reading.

Documents

Datasheets and manuals.

No reviewed documents are published for D348D Plus yet.

Request the current datasheet or manual →

Compare

A different job may need a different meter.

Compare D348D Plus with others

Is this the right meter for your system?

Share your pipe, liquid temperature and connection requirements with our engineers.

Contact Us