D114 · Fixed flow

Robust, cost-effective flow for utilities and irrigation.

The D114 is a robust, cost-effective solution for accurate flow measurement over a wide range of pipe sizes.

D114 ultrasonic measurement instrument

At a glance

What D114 does, in plain words.

What it measures
Liquid flow
How much liquid moves through the pipe.
How it installs
Clamp-on
Sensors fit on the outside of the pipe, so the pipe stays closed.
How it connects
RS485 / 4–20 mA
Wired into control systems over Modbus RS485, or as a 4–20 mA signal.
Pipe sizes
DN25–DN600
DN is the nominal pipe size, roughly the inside diameter in millimetres.

Why D114

D114 in short.

The D114 is a robust, cost-effective solution for accurate flow measurement over a wide range of pipe sizes. With a quick-start menu and a stable signal output, it simplifies routine monitoring and resource management for utility and agricultural irrigation systems.

Where it is used
  • HVAC
  • Process industries
  • Energy management and environmental monitoring
  • Agriculture and irrigation systems
  • Facilities management
  • Industrial maintenance and troubleshooting

How it works

Sound with the flow arrives sooner.

Two sensors on the same side of the pipe take turns sending sound through the water. Sound travelling with the flow arrives slightly sooner than sound travelling against it; the meter turns that time difference into flow, which is why it needs to know your pipe.

Pipe & installation

What the meter needs to know about your pipe.

These are set up on the meter after installation. Pipe size and transducer type are decided when ordering.

Pipe & installation guide pipe materials, sizes, setup checklist

Stainless steel · 2″ example

A smooth metal surface. Clean the spot, add coupling gel, then clamp the sensor on.

60.3mmacross the outside
2.8mmwall thickness
54.8mmacross the inside

Pipe sizes are names, not measurements: a 2″ pipe is 2.375″ across.

The meter needs Pipe size Wall thickness Material: Stainless steel
Technical details standards, OD / ID, both units
Standard
ASME B36.19 · 2″ Sch 10S
Outside diameter (OD)
2.375″ (60.33 mm)
Wall
0.109″ (2.77 mm)
Inside diameter (ID)
2.157″ (54.79 mm)
Meter parameters
OD · wall · material

This guide shows what a clamp-on meter needs to know about a pipe. It does not mean every model fits every pipe: check the specifications below or ask an engineer.

Specifications

Check the fit before you specify.

The short version is above. These are the specifications published for D114; values that are still being checked are left out.

Performance

Flow velocity
0.5–5 m/s (1.6–16 ft/s)
Pipe size
25–600 mm (1″–24″)
Accuracy
±2% of reading (0.5–5 m/s)
Repeatability
0.4%
Pipe material
Carbon steel, stainless steel, PVC, copper

Function

Communication
RS485 with Modbus protocol
Analogue output
4–20 mA, max. load 750 Ω
Power supply
10–36 VDC, 1 A max.

Physical

Ambient temperature
−10 °C to 50 °C (14 °F to 122 °F)
Transducer temperature
0 °C to 60 °C (32 °F to 140 °F)
Ingress protection
Transmitter IP65, transducer IP68
Transducer cable
5 m (16.4 ft) standard

Need a value that is not listed, or the datasheet for your configuration? Ask an engineer.

What these terms mean
DN
Nominal pipe size, roughly the inside diameter in millimetres (DN50 ≈ 50 mm).
Clamp-on
Sensors strap to the outside of the pipe. No cutting, no shutdown for installation.
PoE
Power over Ethernet: one network cable carries power and data.
LoRaWAN
Long-range, low-power wireless. Readings travel through a gateway to a network server.
Modbus RS485
A wired connection widely used by building and industrial control systems.
4–20 mA
An analogue signal where the current represents the reading.

Documents

Datasheets and manuals.

No reviewed documents are published for D114 yet.

Request the current datasheet or manual →