| Specification | |
|---|---|
| What it measures | Flow and thermal energy |
| Typical use | Fixed monitoring |
| Data connection | WiFi |
| Installation type | Clamp-on |
| Pipe sizes | DN25–DN1200 |
| Reviewed specifications | |
| Flow velocity | 0.01–5.0 m/s (0.03–16 ft/s) |
| Pipe size | 25–1200 mm (1″–48″) |
| Accuracy | Flow ±1% of reading (0.5–5 m/s); energy ±2% of reading |
| Repeatability | 0.2% |
| Pipe material | Carbon steel, stainless steel, copper, PVC |
| Communication | RS485 with Modbus protocol |
| Analogue output | 4–20 mA, max. load 750 Ω |
| Pulse output | 0–9999 Hz, OCT, adjustable frequency limits |
| Relay output | Max. 1 Hz, 1 A at 125 VAC or 2 A at 30 VDC |
| Data storage | TF card, more than 1000 days |
| Wireless | WiFi |
| Power supply | 10–36 VDC, 1 A max. |
| Ambient temperature | −10 °C to 50 °C (14 °F to 122 °F) |
| Transducer temperature | 0 °C to 80 °C (32 °F to 176 °F) |
| Temperature sensor | 0 °C to 100 °C (32 °F to 212 °F) |
| Ingress protection | Transmitter IP65, transducer IP68 |
| Transducer cable | 9 m (29.5 ft) standard |